KOVYEL 铠垣
33/35/36kV · OVERHEAD DISTRIBUTION

33kV, 35kV and 36kV Overhead Line Equipment Package

A complete 33/35/36kV overhead line material package for long-distance distribution, utility feeders and EPC tenders, coordinated from structures to cable transition.

Request coordinated proposal →View supply scope
36kV overhead distribution line project scene
Representative application · final configuration follows approved project data
DIRECT PROJECT ANSWER

What is included in a 33kV or 36kV overhead line EPC supply package?

A 33/35/36kV supply package normally combines poles or light towers, AAAC/ACSR conductors, 36kV-class insulators, suspension and tension hardware, joints and dampers, protection and switching equipment, transformer or cable-transition interfaces, earthing, fiber accessories and project-coded shipment documents. The project must confirm whether 36kV or 40.5kV equipment is required.

TYPICAL SYSTEM BASIS

33/35/36kV starting point.

The following values organize the first technical review. They do not replace the utility specification.

Nominal system
33kV, 35kV or 36kV
Equipment class
36kV or 40.5kV
Frequency
50Hz or 60Hz
Structures
Poles or light lattice structures
Communication
OPGW or ADSS as specified
Final selection
Utility-approved design
COORDINATED SUPPLY PACKAGE

Products matched as one line system.

Every group is checked against the same structures, conductors, insulation, equipment interfaces and approved project codes.

01

Line, structure & conductor

Complete route materials for pole or light-tower systems.

  • Concrete or steel poles and light lattice structures
  • Crossarms, brackets and structural fasteners
  • AAAC, ACSR or approved phase conductors
  • Earth wire, OPGW or ADSS systems
  • Guying, anchoring and earthing materials
02

36kV insulation & hardware

Mechanical and electrical assemblies matched to the line design.

  • Composite or porcelain line-post and strain insulators
  • Suspension and tension string hardware
  • Clamps, dead ends, compression joints and repair sleeves
  • Armour rods and vibration dampers
  • Jumper, terminal and cable-transition connectors
03

Protection, equipment & project control

Grid interfaces and controlled project delivery.

  • 36kV surge arresters and fuse cutouts
  • Load-break switches, disconnectors and reclosers
  • 33/11kV or 33/0.4kV transformers
  • 36kV cable terminations and joints
  • Inspection records, BOM coding and export packing
TYPICAL APPLICATIONS

Where this package is used.

  1. 01Long-distance distribution feeders
  2. 02Industrial and mining power supply
  3. 03Utility network reinforcement
  4. 04Rural electrification backbone feeders
  5. 05Overhead-to-cable transition projects
TECHNICAL COORDINATION

Interfaces to close before final quotation.

01

Confirm the highest equipment voltage before selecting arresters, switches, insulators and cable accessories.

02

Use the pole schedule to separate tangent, angle, dead-end, terminal and transformer structures.

03

Coordinate conductor mechanical data with string hardware, compression tooling and vibration control.

04

Check whether the communication system uses OPGW, ADSS or a separate telecom route.

RFQ INPUTS

Information the buyer should provide.

Unknown fields may be marked “to be confirmed,” but they should remain visible in the clarification list.

  1. 01Nominal and highest equipment voltage
  2. 02Single-line diagram
  3. 03Pole/tower schedule and drawings
  4. 04Conductor and earth-wire data
  5. 05Insulation level and creepage requirement
  6. 06Switchgear, transformer and cable-interface ratings
  7. 07OPGW or ADSS requirement
  8. 08BOQ, standards, quantities and destination
STANDARDS & SPECIFICATIONS

Confirmed product by product.

IEC 61089 · stranded overhead conductorsIEC 61284 · overhead line fittingsIEC 60383 / IEC 61109 · insulatorsIEC 60099-4 · surge arrestersIEC 62271 series · high-voltage switchgearIEC 60076 · power transformers
RELATED PRODUCT SYSTEMS

Continue into the detailed catalogue.

InsulatorsOverhead line fittingsTransformers
BUYER QUESTIONS

Direct answers for 33/35/36kV procurement.

Is 33kV equipment always rated 36kV?

36kV is common, but some projects specify 40.5kV. The tender and utility specification must confirm the equipment class.

Can a project include both poles and lattice structures?

Yes. The route can use different structure families, but every structure type needs its own bill of materials and attachment interfaces.

Can KOVYEL coordinate the cable-transition package?

Yes when cable type, conductor size, insulation level, termination arrangement, sealing-end support and earthing details are provided.

READY TO REVIEW THE 33/35/36kV PROJECT?

Send the BOQ, drawings and technical specification.

Prepare project inquiry →